Water Insulation Products
SUMAX TURBO LASTIC
Technical Data Sheet Material Safety Form
CEMENT AND ACRYLIC BASED, TWO COMPONENT, HIGH ELASTICITY, QUICK SETUP WATER INSULATION MORTAR
 
Product Description:
Cement and acrylic based, two-component, high elasticity, applicable to positive and negative water pressure, UV resistant, quick setting waterproofing mortar independent of weather conditions.

TS EN 1504-2 (C) I MC-IR principles,
TS EN 14891 suitable.

Public Works Pose No: 04477/2

Areas of Use:
Indoor and outdoor,
Vertical and horizontal applications,
In applications on cement-based plasters, screeds, exposed concrete, old ceramics coatings, etc.
In applications against positive and negative water pressure in foundation, curtain and basement floors of all buildings,
On terraces and balconies,
In wet areas such as WC, bathroom, kitchen,
In swimming pools,
Water tanks and wastewater tanks,
Elevator pits,
In wet areas against ground moisture, leakage applications,
It is used for bonding protective plate.


Features:
Bituminous thick coating with waterproofing properties, bitumen free waterproofing material.
It can be applied to old bituminous surfaces and mineral surfaces.
It has very high elasticity and crack bridging feature.
It is capable of crack-bridging even at low temperatures.
Resistant to positive and negative water pressure.
Fast setting independent of weather conditions.
Provides resistance to rain and pedestrian traffic after 4 hours, can be covered.
It shows a minimum of thinning during drying.
It gets a crack-free socket without shrinkage even under wind and sun.
Provides the advantage of comfortable and quick ending in large areas.
Resistant to external weather conditions, frost, and UV.
It can be applied on damp surfaces without a primer.
Can be used in areas affected by movement and vibration.
Due to its high adhesion performance and flexibility, it forms a waterproof layer under screed and ceramic.
It forms a jointless, seamless, permanent, waterproof coating.
Resistant to chemicals and salt solutions in soil.
Water vapor permeable.
Durability is high.
It can be applied by brush, trowel or spraying machine.
Resistant to the freeze-thaw cycle.

Technical Specifications:
Structure of Material:
Component A: Special cement and chemicals
Component B: Copolymer Acrylic
View: Dark Gray Powder
Adhesion Strength: ≥ 1.00 N / mm²
Pressurized Water Resistance: ≥ 5 bar 
Capillary Water Absorption: ≤ 0.1 g (after 4 hours)
Crack Bridging: ≥ 2 mm
Application Temperature: +5ºC to +35ºC
Service Temperature: -20ºC to +80ºC
Mortar Resting Time: 3-5 min.
Use Time: 45 minutes 
Waiting Between Floors: 1-3 hours 
Resistance to Rain: 4 hours 
(In the absence of accumulated water)
Covering: (Plaster, Ceramic, etc.) 
Outdoors: 4 Hours
Indoor Areas: 24 Hours
Time to put into service 
Mechanical Strength: 3 Days
Water Impermeability: 7 Days
The above values are given at +23 ºC and 50% relative humidity.

Pre-Application Preparation: 
Take care of that the application surface is cured and intact.
The application surface should be cleaned from paint, oil, dust, etc. materials.
Plasters that are not well adhered on the application surface should be removed, If there are defects  they should becorrected with repair mortars.
Active water leaks should be filled with suitable products.
Corners and edges should be chamfered at least 4 cm radius.
The application surface should thoroughly be wet, wait until wet-dry.
If the coating material immediately loses its water and becomes dull, it is understood that the surface is not sufficiently wetted or dries quickly.
In such cases, when the air is hot or the material is left in the wind, water can be added only up to 10% of component B can be added to the mixed material for the first layer.
On multi-hole surfaces Sumax Turbo Lastic The surface is smoothed by pulling a trowel, and normal application can be done after drying.

Mixture Ratio: 
Component A: 10 Kg.
Component B: 10 Kg.

Application
10 kg liquid component is added to 10 kg cement-based powder component and mixed with a low-speed mixer until the lumps are completely removed. Mix 10-20% less liquid component for trowel application.
It is suspended 3-5 minutes to complete the chemical reaction. 
Mix again before use. 
It is applied with a mortar, brush, roller or trowel.
Consume the prepared mortar within at the latest 30-45 min.
The prepared mixture is applied in 2 or 3 layers with the help of brush and roller. 
The direction of brush application on each layer should be perpendicular to each other. 
Wait about 1-3 hours for 2 coats application with brush or roller, application between layers. 
Waiting time between coats may vary depending on ambient conditions.
The second coat should be applied after the first coat is dried in such a way that it is not damaged.
In application, wet film thickness should not exceed 2 mm in one layer. 
The application should be done in at least 2 coats. 
Ovalize the corner joints in the application area and reinforce the mortar with mesh.
The mesh can be placed between the application to meet the tensile stresses and create a more flexible waterproofing layer on mobile floors with the risk of cracking.
Waterproof, flexible insulation joint tape should be applied to prevent cracks and water leaks that may occur in cold joints in the joints of structural elements. At least 2 cm wider than the width of the tape to be applied to these joints Sumax Turbo Lastic are applied. Insulation joint tape is placed on the wet material, and it is pressed on the tape with a suitable trowel and adhered in such a way that there is no space left under it. On the tape by applying Sumax Turbo Lastic detail is completed.
In wet volume applications, moving points and vertical and horizontal corners can be supported with corner insulation tapes.
The working and reaction times of cement and acrylic-based systems are affected by ambient and ground temperature and relative humidity in the air. 
The reaction slows down at low temperatures, which increases the pot life and working time. 
Higher temperatures accelerate the chemical reaction, and the above times are shortened accordingly. 
For the material to complete its cure, the ambient and surface temperature must not fall below the minimum allowable temperature.
Sumax Turbo Lastic of can be plastered or painted with solvent-free paints that are diffusion-resistant.

Warnings
Avoid application at temperatures below +5ºC and above +35ºC.
Newly completed applications should be protected against adverse weather effects such as direct sunlight, excessive airflow, high air temperature (above +35ºC), rain, and frost.
If left open It should not be exposed to point or linear loads if left open.
Sumax Turbo Lastic earth fill should not be applied without applying for protection on the applied basic curtain walls.
Avoid direct contact with water in the first 4 hours of the completed application.
Do not add any additives other than its liquid component to the powder mortar.
Never add powder and water to the expired or crusted mortar in the container, discard the mortar.
Wash all tools and application equipment with clean water immediately after use.

Consumption
First Floor Consumption: 1,0-1,5 kg / m² (For 1 mm thickness) 
Second Floor Consumption: 1,0-1,5 kg / m² (For 1 mm thickness) 
Third Floor Consumption: 1.0-1.5 kg / m² (For 1 mm thickness) 
Consumption amount is theoretically calculated values in laboratory environment; we recommend the application of consumption control sample before application.

Packing
20 Kg. plastic bucket
A Powder Component: 10 kg 
B Liquid Component: 10 kg 

Storage and Shelf Life :
1 year from the production date in dry and moisture-free environments. The package should be tightly closed when not in use. Packages must be protected from frost.                                                                                         

Safety Advices: 
For more detailed information, please refer to the Safety Data Sheet.

Responsibility
The application instructions and technical values given in this technical document are based solely on our scientific and practical knowledge. These values may vary depending on the ambient conditions. Allmax Construction Chemicals reserves the right to make changes in the products in line with technological developments. Any consequences other than the written recommendations regarding where and how the product will be used and / or due to misuse Allmax Construction Chemicals can not be held responsible. Therefore Allmax Construction Chemicals products, make sure you use the right product in the right place. Allmax Construction Chemicals is only responsible for the quality of the product.