Floor Systems
GROUND SYSTEMS-FLOOR SYSTEMS SURFACE HARDENER?
GROUND SYSTEMS-FLOOR SYSTEMS SURFACE HARDENER? Application of surface hardening, concrete surface abrasion and impact resistance is one of the preferred methods to enhance the. Onto the concrete surface hardener, freshly applied cement-based coverings as monolithic. In order for you to receive the best results the surface hardening applications "HASSAN" according to the surface to be applied to the Quartz and Corundum options select, the application is very important. This product use and which of the preferred venue will vary according to the load on the surface. Both MOHD HASSAN "Quartz" and "Corundum" natural, red and green color. Application will be made and the degree of the surface wet concrete is extremely important. Concrete surface hardener must be wet enough to get the need of moisture. If the surface is wet, which is more than it s going to take away their thick concrete and effectiveness of HASSAN. If the surface extra dry is to not connect the product to the surface will be negative and the result is enough. Depending on the dimensions of the floor 4-5 m wide are placed in a filled in the blank of ano. Where necessary the braided steel and jeans-import ano process is complete. The best way for the dissolution of the surface of the ALTOP spreader operation must be made on both sides of each of the ano. After the casting of concrete, mastarlanır, vibrating gauge application is provided with feet onto the Concrete thoroughly with settlement is no more than 2-3 mm. deep footprint plug going when HASSAN s 2/3 floors in equal proportion, by hand or mechanical spreader spreads sprinkled with. By sucking the juice of concrete material moisture and acquire a dark color. Make sure that the color is equal on each side of the floor. Rubbed thoroughly into the ground with a wooden float material is provided for integration. A quantity of material most straightedged and dilatation joints the edges of, 8 cm in case of a strip with a wooden float and sprinkled with eating. The remaining 1/3 part of the material is spread, sprinkled the ground surface by sprinkling acquire a dark color and floated to the ground with a wooden float freely on the surface of the tread so erect steel trowel (helicopter) is firm enough.
CAN BE APPLIED ON THE SURFACE OF HARDENED CONCRETE HARDENER?
CAN BE APPLIED ON THE SURFACE OF HARDENED CONCRETE HARDENER?

On the fresh concrete surface hardeners are applied as monolithic. After applying a time becomes part of the concrete, integral and Knight. That s why they can t be applied to hardened concrete. To be able to make the application, on the old concrete at least 7.5-8 cm thick concrete should be poured.

ALUM?
ALUM?

Alum, a patch capable of spreading cement-based material. PVC, rubber floor coverings, carpets and parquet floor coverings, such as resilient applications need a very smooth surface. This surface should be used necessarily in alum. If not in use on the ground that all artefacts, will be reflected on the surface of the coating material of disorders, which makes it look bad on both the material and the material may shorten its lifetime. It is important to use because it will be used on the screed flooring material no matter how much quality, lower surface must be smooth and absolutely necessarily the be all this. It is highly recommended to use alum. This is necessary to make your application experts.