Decorative Coatings
ALLDECO C3
Technical Data Sheet Material Safety Form
STRIPED DECORATIVE PLASTER - THICK

 
Product Description:
White cement-based, polymer and fiber-added, highly water-repellent, line pattern decorative facade coating specially developed for sheathing systems.

It is suitable for TS 7847 standards.

Public Works Pos No: 04.476/A

Areas of Use:
As the last layer coating material in sheathing systems,
It is used as a decorative coating on interior and exterior facades.

Features:
It is highly water repellent.
It is resistant to external effects and frost.
It has the ability to breathe thanks to its vapor permeability.
It provides fast and easy application with its comfortable application and spreading feature.
When applied in accordance with the application conditions;
Thanks to the special filling distribution, a homogeneous pattern is obtained on the facade.
It has high adherence and strength.
It does not crack and spill thanks to its special filling size, polymer and fiber.
It can be painted over after it dries.

Technical Spesifications:
Appearance: White Powder
Dry Unit Weight: 1.6 ± 0.2 kg / m³
Application Temperature: + 5ºC to + 35ºC
Application Thickness: 1.2 mm
Water Mixing Ratio: 6.0-7.0 Liter / Bag
Rest Time of Mortar: 2-3 min.
Pot Life: 1-2 hours
Working Time: 20-30 min.
Drying Time: 24 hours.
Compressive Strength: ≥ 3 N / mm²
Flexural Strength: ≥ 1.5 N / mm²
Temperature Resistance: -25 C to + 80 C
The above values are given for +23 ºC and 50% relative humidity.
Dry Film Thickness: E5
By Grain Size: S4
Water Vapor Transfer Rate: V1
Water Transfer Rate: W2
Crack Covering Feature: A0
Carbon Dioxide Permeability: C0
Resistance to Mold Growth: K2
The above values are classified according to TS EN 1062-1.

Pre-Application Preparation
Care must be taken that the application surface is cured and solid.
The application surface should be free from materials such as dust, oil, paint that prevent adhesion.
Allmax thermal insulation plasters should be applied with a thickness of 4 mm, at least 72 hours (after complete drying).
Decorative plaster primer should be applied in thermal insulation systems before applying the decorative coating.
In applications other than the thermal insulation system, sub-surfaces such as cracked plasters and weak surfaces that are not strong enough to carry the application should be cleaned from the application surface.
The floors that require repair should be repaired with special repair mortars at least 3-4 days before the adhesive is applied.
In hot weather, the application surface should be wetted and care should be taken to keep it moist.
If the surface is very absorbent, it is recommended to use a primer on the surface.

Application
Pour 25 kg of Alldeco C3, Decorative Plaster into a container of approximately 6.0-7.0 liters of water and mix it with a low-speed mixer or trowel until a lump-free mixture is obtained.
During the mixture, any additives not specified in the application instructions should not be added.
The prepared mortar is 2-3 minutes. Let it rest for maturity and again 1-2 minutes. It should be mixed until it becomes homogeneous.
The mixture in the pot should be consumed within about 1 hour.
Decorative plaster should be applied to the surface with a steel trowel and spread over the entire surface in equal thickness.
Application thickness should be adjusted according to the largest aggregate.
Pattern can be given by making horizontal, vertical or circular movements according to the desired texture direction with a plastic trowel without shrinking the material applied to the application surface completely (shrinkage of the material varies depending on weather conditions). While patterning, the application should not be interrupted and the trowel surface should be scraped frequently.
After drying, it can be painted with an optional, solvent-free exterior paint.

Warnings
It should be applied without interruption on wide facades and with sufficient personnel.
At the points that require a compulsory finish on the facade, the boundaries should be determined with a protective tape and the application should be made.
During the application of the final coatings, it should be prevented from drying quickly due to adverse weather conditions.
In order to prevent rapid and unhealthy drying, the plastered surfaces should be protected from direct sunlight, heavy weather conditions such as strong wind, hail and frost.
In order to achieve the expected and desired long-term performance of the product, after the completion of the entire application, a coating suitable for the purpose and detail of the work as soon as possible (3-7 days depending on the drying time of the applied product (low temperature, high relative humidity prolongs the drying time). (paint etc.) application should be protected or covered.
Paint primer should be used in dark color paint applications. The entire coating surface should be painted in 2 layers in order to prevent applications that may cause a color tone difference.
Paint consumption may vary depending on the pattern. Color should be checked before application.

Consumption: 3,50-4,50 kg/m²
The amount of consumption is the values calculated theoretically in the laboratory environment; We recommend that consumption control sample application be made before the application.
Packing: 25 kg craft bags.

Storage and Shelf Life: 
It should be stored in its unopened original package, in a cool and dry environment, protected from frost. For short term storage, maximum 3 palettes should be placed on top of each other and the shipment should be made on a first in, first out system.
Palettes should not be stacked on top of each other during long term storage.
It is 12 months from the date of production under suitable storage conditions.
Opened packages should be stored under appropriate storage conditions and used within one week.

Safety Advices
For more detailed information, please refer to the Safety Data Sheet.

Responsibility
The application instructions and technical values given in this technical document are based entirely on our scientific and practical knowledge. These values may vary depending on the ambient conditions. Allmax Construction Chemicals reserves the right to make changes in products in line with technological developments. Allmax Yapı Kimyasalları cannot be held responsible for the results that may arise out of written recommendations regarding where and how the product will be used and / or due to incorrect use. Therefore, when using Allmax Construction Chemicals products, make sure that you use the right product in the right place. Allmax Construction Chemicals is only responsible for the quality of the product.